Question 1: The way to use it is roughly from coarse to fine, so does it filter out everything by directly loading the fine one? Yes, but the blockage will be finished soon because of the size of the filter.
Question 2: filter replacement time? Generally speaking, the use of 1.5 ~ 2 years or differential pressure up to 0.7 ~ 1kg / cm2, activated carbon cartridge series when the taste of oil mist appears clearly, the above to see what comes first. (If you are a 24-hour factory and long time gas consumption is recommended to shorten the replacement time).
Question 3: What if the differential pressure is used as the basis for replacement? Can but, do not be happy too early, must be regularly read the meter records, differential pressure is just a basis but is not absolute, differential pressure according to the time to make more and more large when one day to see the differential pressure suddenly become smaller, that will be what happens to the filter?
Question 4: Do I have to install them all from thick to thin? If you do not consider the cost, it does not matter. After all, the air filter is not cheap, that to install to what extent that depends on the industry to determine the cleanliness of the air.
Question 5: How to remove the oil or water inside the filter? There are many kinds of drainage methods for filtration, which are commonly used for introduction:
Manual drainage type: there is a manual valve at the bottom which needs to be manually discharged periodically.
Self-draining type: there is a float-type drainer inside the filter which will be automatically discharged when the water fills up to a certain level, but it is easy to fail after mixing oil and water.
External automatic drain: from the bottom of the manual valve installed another automatic drain, the same float-type drain when the water is full to a certain level will be automatically discharged, but the oil and water mixing is easy to fail.
Differential pressure type: when the system pressure relief filter internal differential pressure thimble will rise, at this time the water will be discharged. But if the pressure state has been full water level can not be discharged.
Others such as timed solenoid valve type, timed electric ball valve type, motor type, detection level type...etc..